Aeration system for water storage tanks

Integrated system with diaphragm blower/compressor, disc diffusers, and an optional timed control panel for circulating and aerating stored water, reducing stagnation and odours. The housing cabinet is not included.

Learn more
Aeration system for water storage tanks, Rototec

Main specifications and fields of application

Intended use

  • Aeration of storage tanks for rainwater or treated water
  • Prevention of stagnation and unpleasant odours by injecting clean air at depth
  • Applications in activated sludge treatment plants

Available kits

  • KITAIR40 – HP40 blower + 1 IFADN disc diffuser + QST panel
  • KITAIR60 – HP60 blower + 2 IFADN discs + QST panel
  • KITAIR80 – HP80 blower + 4 IFADN discs + QST panel

Installation

  • Connect the air hose to the blower and to the tank quick coupling. Install the blower indoors, above ground, on a solid base, within 10 m of the plant and above tank level. Power supply 230 V – 50 Hz with dedicated protections. Provide conduits: air ≥ Ø80 mm, electrical ≥ Ø63 mm.

Features of the aeration system for water storage tanks

Light and practical

No welding or wiring inside the tank: quick connections, low noise, and low power consumption with the diaphragm blower.

Versatile operation

Continuous or timed operation (QST panel with 24-h timer) to match hydraulic/organic loads.

DiFine diffusion and efficiency

Membrane disc diffuser with micro-perforations (1–3 mm, ~8,300 holes), airflow 1.5–8.5 m³/h, large diffusion area and low head loss.

Low maintenance

Blower filter to be cleaned quarterly; diffuser can be cleaned with a water jet during sludge purging.

Detailed technical specifications

Materials

Main components: diaphragm blower/compressor, rubber tubing, micro-perforated rubber (EPDM) disc diffuser; IP67 control panel (on request).

Thermal / operating range

Blower: ambient temperature −20 to +40 °C, low humidity

Diffuser: operating temperature 0 to 100 °C

QST panel: IP67 enclosure for installation in a protected environment

Installation and maintenance

Install the blower in a covered, ventilated technical room, free from corrosive gases and vibrations. After start-up, run 24/7 for 2–3 months, then time 2 h ON / 30 min OFF across the day. Perform periodic cleaning of the filter and diffuser; use original parts for any replacements.

Technical table

By clicking on the item code, you can access the page with any technical attachments: Technical drawing (PDF) and/or Technical drawing (DWG).

ItemBlowerPiatto diffusoreN° Piatti diffusoriQuadro elettrico
KITAIR40HP40IFADN1QST
KITAIR60HP60IFADN2QST
KITAIR80HP80IFADN4QST